Window film

Film for a house or a small building: windows, skylights and glass doors, film area per type, safety film anchoring.

No credit card. Cancel anytime.

Feet and inches or metric: your choice. One switch on the sheet converts every measurement.

Window film: a filled-in survey in MesuPro
Window film: the same sheet on a phone
A survey made with this template, in the app.

What you measure

The template's tables and their columns, as the app shows them. Calculated columns fill in as you type.

Window Measurements

  • Window Width
  • Window Height
  • Film Opacity %
  • Quantity
  • Installation Notes
  • Total Area calculated
  • Film product
  • VLT (%)
  • Area of one pane calculated
  • Panes over 40 sq ft (3.7 m²) calculated

Skylights and horizontal glass

  • Glass width
  • Glass length
  • Film Opacity %
  • Quantity
  • Installation Notes
  • Total Area calculated
  • Film product
  • VLT (%)
  • Area of one pane calculated
  • Panes over 40 sq ft (3.7 m²) calculated

Glass doors and partitions

  • Glass width
  • Glass height
  • Film Opacity %
  • Quantity
  • Installation Notes
  • Total Area calculated
  • Film product
  • VLT (%)
  • Area of one pane calculated
  • Panes over 40 sq ft (3.7 m²) calculated

Safety film anchoring

  • Opening
  • InstallationChoices: Daylight Edge to edge Mechanical, bar and batten Mechanical, adhesive gasket Wet glazed
  • Panes
  • Glass width
  • Glass height
  • Width sides anchored
  • Height sides anchored
  • Anchored length calculated
  • Glass thickness
  • FrameChoices: Aluminum Steel Wood Vinyl Other
  • Frame conditionChoices: Sound Gasket worn or loose Frame to repair
  • Notes

See these tables calculate with your own measurements, no account.

Try this template

More templates: Windows and window film

Windows and doors: replacement measure⁠

The windows and doors of a house, room by room: replacement type, three readings with the smallest kept, squareness, depth, hinges and glass.

You get: Area

Windows: commercial building survey⁠

A window measurement template: one section per facade, one row per opening, the glazed area and perimeter per facade and for the building.

You get: Opening area Caulk perimeter

Commercial window film⁠

Film for multi-story buildings, floor by floor: glass area, film product and linear elements.

You get: Glass Surface Area Total Area Panes over 40 sq ft

About this template

Measure each window and get the film area to install.

Guide and sources

Read the guide and sources

Measure the visible glass of each pane (the daylight opening), not the window frame. The film is cut a little larger and trimmed in place, leaving a gap of about 1/16 in at the edge.

Note on each row the film product, as named on the maker's data sheet, and its VLT, the share of visible light it lets through.

Note each pane: single or sealed unit; annealed, heat-strengthened, tempered (look for the etched mark in a corner; without one, check the glass type before installing), laminated or wired; clear, tinted or reflective; and the low-e coating, if any. Where it sits varies from window to window: check compatibility against the glass or film maker's warranty conditions.

Without the film maker's own guidance, IWFA does not recommend a solar film on an annealed sealed unit over 40 sq ft (3.7 m²) or a single annealed pane over 100 sq ft (9.3 m²). Thick, tinted or partly shaded glass also needs a suitability check before installing.

Film comes in rolls 36 to 72 in wide and 100 ft long. Warranties depend on the film and its use: follow the film maker's installation rules to keep it.

Safety film anchoring has a section of its own, one row per kind of opening: the installation (the IWFA names daylight, edge to edge, mechanical with a bar and batten or an adhesive gasket, and wet glazed, where the sealant goes onto the film and the frame by 3/16 in or more), the panes, the glass width and height, the width and height sides anchored, so the anchored length, the glass thickness, the frame and its condition. The IWFA says tempered glass needs more than a daylight installation to stay in the frame, leaves thick safety film outside its guide, and leaves the choice of products to a competent security design professional. The sheet records; it promises no strength.

Sources

  • IWFA, safety and security guide Trade associationIWFA Safety & Security Education Guide, International Window Film Association (IWFA), 2026. Checked Oct 7, 2026
  • IWFA, visual inspection Trade associationIWFA Architectural Visual Inspection Guideline for Applied Window Film, International Window Film Association (IWFA), 2020-01-01. Checked Oct 7, 2026
  • IWFA, advanced solar guide Trade associationIWFA Advanced Solar Control Education Guide, International Window Film Association (IWFA), 2026. Checked Oct 9, 2026
  • IWFA, solar control guide Trade associationIWFA Flat Glass Solar Control Education Guide, International Window Film Association (IWFA), January 2023. Checked Oct 7, 2026
  • CPSC 16 CFR 1201 GovernmentCPSC 16 CFR 1201, Safety standard for architectural glazing materials, US Consumer Product Safety Commission, current CFR. Checked Oct 7, 2026
  • CAN/CGSB-12.1 paywalled StandardCAN/CGSB-12.1 Safety glazing, Canadian General Standards Board, 2017. Checked Nov 12, 2026

Your trade isn't listed? The AI assistant builds your form.

No credit card. Cancel anytime.