Windows: commercial building survey

A window measurement template: one section per facade, one row per opening, the glazed area and perimeter per facade and for the building.

No credit card. Cancel anytime.

Feet and inches or metric: your choice. One switch on the sheet converts every measurement.

Windows: commercial building survey: a filled-in survey in MesuPro
Windows: commercial building survey: the same sheet on a phone
A survey made with this template, in the app.

What you measure

The template's tables and their columns, as the app shows them. Calculated columns fill in as you type.

Openings

  • Mark
  • TypeChoices: Fixed Fixed over awning Casement Awning Hopper Projected Single hung Sliding Storefront Aluminum entrance door Curtain wall (glazed)
  • Width (masonry opening)
  • Height (masonry opening)
  • Quantity
  • Area per unit calculated
  • United inches (W + H) calculated
  • Opening area calculated
  • Caulk perimeter calculated
  • ConditionChoices: Good Monitor Replace
  • FrameChoices: Aluminum Steel Wood Vinyl Clad
  • GlazingChoices: Single Double (insulated) Triple (insulated) Laminated Tempered Wired (check the code) Low-E
  • PanesChoices: Single Double (sealed unit) Triple (sealed unit)
  • Glass typeChoices: Annealed Heat-strengthened Tempered Laminated Wired (check the code)
  • Low-e coatingChoices: Yes No Unknown
  • Safety glazing locationChoices: Yes No
  • DeficienciesChoices: None observed Sealed unit failure (fogging) Broken or cracked glass Condensation or frost Air leakage Water infiltration Frame corrosion or rot Thermal break failure Hardware or operation Weatherstripping Perimeter sealant failure Glazing putty or gasket failure Blocked weep holes
  • Notes

See these tables calculate with your own measurements, no account.

Try this template

More templates: Windows and window film

Windows and doors: replacement measure⁠

The windows and doors of a house, room by room: replacement type, three readings with the smallest kept, squareness, depth, hinges and glass.

You get: Area

Commercial window film⁠

Film for multi-story buildings, floor by floor: glass area, film product and linear elements.

You get: Glass Surface Area Total Area Panes over 40 sq ft

Window film⁠

Film for a house or a small building: windows, skylights and glass doors, film area per type, safety film anchoring.

You get: Total Area Panes over 40 sq ft Anchored length

About this template

One section per facade with a subsection per floor, and one row per opening: mark, type, width, height and quantity of the masonry opening give the opening area and the caulk perimeter, with the area per unit, united inches, condition, frame, panes, glass, low-e coating, safety glazing location and deficiencies, and totals per facade and for the whole building. A building form, filled once, holds the name, address, year built, wind exposure, climate zone and the PCB and asbestos checks.

Guide and sources

Read the guide and sources

Measure each opening three times across and three times up, then keep the smallest of each; the readings should agree within 1/8 in. Note where you measured: masonry opening, rough opening, existing frame or glass. Never assume two look-alike windows are the same size.

The supplier deducts a clearance from your smallest measure, about 1/4 to 5/8 in per side depending on the product. Codes count fenestration area on the rough opening; curtain walls to mullion centrelines.

The perimeter is measured once and sealed twice: outside with backer rod and sealant, inside with an air seal.

For the right performance class (CW or AW for most commercial buildings), note the storeys, each opening's height above the ground and the wind exposure: open or rough terrain in the NBC, exposure B, C or D in ASCE 7, with hills and escarpments raising the load. MesuPro does not compute the wind class; the supplier does. The energy code's climate zone sets the thermal targets: 4 to 8 in Quebec, 1 to 8 with A, B or C by county in the US. Storefronts and curtain walls are separate systems, outside the window standard.

Glass in or near doors, large low panes and stair glazing must be safety glass; wired glass no longer qualifies. Caulk applied from about 1950 to 1979 may contain PCBs, and old glazing putty and caulk can contain asbestos: have them tested before removal, and note the results in the building form.

Sources

  • NAFS (101/I.S.2/A440) paywalled StandardNAFS, North American Fenestration Standard AAMA/WDMA/CSA 101/I.S.2/A440, FGIA, WDMA, CSA Group, 2022 (5th ed.). Checked Oct 7, 2026
  • Jeld-Wen, measuring guide Manufacturer dataJeld-Wen, Measurement guide for new construction and replacement windows, Jeld-Wen, JMI003. Checked Oct 7, 2026
  • AAMA 2410 paywalled StandardAAMA 2410, Standard practice for installation of windows with an exterior flush fin over an existing window frame, FGIA (AAMA), 2410-13. Checked Oct 7, 2026
  • Marvin, measuring instruction Manufacturer dataMarvin, measuring instruction 19915808, Marvin, 2019. Checked Oct 7, 2026
  • United inches (dealer pricing) Rule of thumbWindow dealer price sheet using united inches, Window dealer (publisher not identified), n.d.. Checked Oct 7, 2026
  • Pella, opening clearance Manufacturer dataPella, Rough opening clearance recommendations, Pella, 2024. Checked Oct 7, 2026
  • Efficient Windows, frame types Trade associationEfficient Windows Collaborative, Window frame types and spacers, Efficient Windows Collaborative, online guide. Checked Nov 11, 2026
  • IBC 2021, 2406.1.1 and 2406.2 CodeInternational Building Code 2021, 2406.1.1 and 2406.2 Impact test (as adopted in the 2021 Seattle Building Code), City of Seattle (IBC 2021 basis), 2021. Checked Nov 12, 2026
  • IBC 2021, 2406 CodeInternational Building Code 2021, Section 2406 Safety glazing, International Code Council, 2021. Checked Nov 11, 2026
  • EPA, PCBs in caulk GovernmentUS EPA, PCBs in building materials: determining the presence of manufactured PCB products, fact sheet, US Environmental Protection Agency, May 2021. Checked Nov 11, 2026
  • ASCE 7-22 paywalled StandardASCE/SEI 7-22, Minimum design loads and associated criteria for buildings and other structures, American Society of Civil Engineers, 2022. Checked Oct 7, 2026
  • DOE, climate regions by county GovernmentBuilding America Best Practices Series vol. 7.3, Guide to determining climate regions by county, US Department of Energy / PNNL, August 2015. Checked Oct 7, 2026
  • EPA-530-R-23-015 GovernmentUS EPA, Technical guidance for determining the presence of manufactured PCB products in buildings, EPA-530-R-23-015, US Environmental Protection Agency, September 2023. Checked Oct 7, 2026
  • EPA, asbestos in window caulk GovernmentUS EPA, How EPA's asbestos regulations apply to window caulk, glazing compound, wiring and other similar materials, US Environmental Protection Agency, updated 2025-11-06. Checked Oct 7, 2026
  • Jeld-Wen Canada, size guide (FR) Manufacturer dataJeld-Wen Canada, Guide de dimensions, Jeld-Wen Canada, 12C-340F (01/15). Checked Oct 14, 2026
  • NBC Part 9 (BCBC 2018), 9.6 and 9.7 CodeNational Building Code Part 9 text as adopted in the BC Building Code 2018, 9.6.1 and 9.7, Province of British Columbia (NBC basis), 2018. Checked Nov 11, 2026
  • CAN/CGSB-12.1 paywalled StandardCAN/CGSB-12.1 Safety glazing, Canadian General Standards Board, 2017. Checked Nov 12, 2026
  • NBC 2020, 3.3.1.20 CodeNational Building Code of Canada 2020, 3.3.1.20 Doors, National Research Council of Canada, 2020 (Quebec: Code de construction, chapitre I, in force 2025-04-17). Checked Nov 12, 2026
  • NBC 2020, 9.6.1.4 CodeNational Building Code of Canada 2020, 9.6.1.4 Types of Glazing and Protection of Glazing, National Research Council of Canada, 2020 (Quebec: Code de construction, chapitre I, in force 2025-04-17). Checked Nov 12, 2026
  • SOR/2008-273 (PCB) GovernmentPCB Regulations, SOR/2008-273, Government of Canada (ECCC), current to 2026-09-21. Checked Oct 7, 2026
  • BCBC 2018, 4.1.7 (NBC wind) CodeBritish Columbia Building Code 2018, Part 4, 4.1.7 Wind load (NBC basis), Province of British Columbia (NBC basis), 2018. Checked Oct 7, 2026
  • Quebec Construction Code, ch. I.1 CodeCode de construction du Québec, chapitre I.1, Efficacité énergétique du bâtiment (Gazette officielle du Québec, 13 mai 2020), Gouvernement du Québec (RBQ), 2020, updated to NECB 2020 on 2024-07-13. Checked Oct 7, 2026