Free blown-in attic insulation calculator: R-value to add, bags and vents
Get the R-value to add to an attic, the bags of blown-in fiberglass or cellulose to buy and the vent area the code asks for, in seconds, free and without an account. Pick your product (AttiCat, ProCat, Climate Pro, InsulSafe SP, Greenfiber cellulose, or ProPink and ThermoShield in Canada): the coverage per bag and minimum thickness fill in from the maker's chart. One row per attic area: its length, width and the R of the insulation already there. Enter the target: the calculation gives the R to add and the bags. For another product, enter the values from its bag. In meters, everything switches to RSI. Pick your code's vent rule, or enter its ratio: the calculation gives the net free vent area the attic needs. Each area's line shows its own R to add, bags and vents.
Updated
The whole job, not only this calculation
For insulation contractors and their crews, the template does what this page cannot: the whole job on one sheet, every measurement on its own line, saved in the client's project with a PDF or Excel report.
- Insulation survey: Attic, walls, foundation and rim joists: existing and target R-value, bags or units per product, vents, hazards and air sealing.
- MesuPro for insulation contractors: every template of the trade, the demo and the report
Makers' charts, products sold in the US (reference)
The coverage charts of loose-fill attic insulation bags the calculator uses, here at R-38, R-49 and R-60: the calculator reads every row of the chart. The chart requires both the bag count and the thickness.
| Product | R | Minimum thickness | Coverage per bag |
|---|---|---|---|
| AttiCat | 38 | 13 in | 51.4 sq ft |
| AttiCat | 49 | 16.5 in | 38.8 sq ft |
| AttiCat | 60 | 20 in | 31.1 sq ft |
| ProCat | 38 | 13.25 in | 60.9 sq ft |
| ProCat | 49 | 16.5 in | 46.4 sq ft |
| ProCat | 60 | 19.75 in | 36.9 sq ft |
| Climate Pro | 38 | 13.4 in | 57 sq ft |
| Climate Pro | 49 | 16.9 in | 43 sq ft |
| Climate Pro | 60 | 20.2 in | 34 sq ft |
| InsulSafe SP | 38 | 14.5 in | 55.7 sq ft |
| InsulSafe SP | 49 | 18.25 in | 42.6 sq ft |
| InsulSafe SP | 60 | 21.75 in | 34.5 sq ft |
| Greenfiber INS541LD | 38 | 11.97 in | 16.4 sq ft |
| Greenfiber INS541LD | 49 | 15.2 in | 12 sq ft |
| Greenfiber INS541LD | 60 | 18.37 in | 9.3 sq ft |
Sources: Owens Corning, AttiCat; Owens Corning, ProCat; Johns Manville, Climate Pro; CertainTeed, InsulSafe SP; Greenfiber, INS541LD cellulose
In Canada: makers' charts in RSI (reference)
The same charts in RSI, millimeters and square meters per bag, here at RSI 7, 8.8 and 10.5 (R 40, 50 and 60). Owens Corning notes the coverage may rise 2 to 10% with joist correction factors.
| Product | RSI | Minimum thickness | Coverage per bag |
|---|---|---|---|
| ProPink | 7.0 | 372 mm | 4.85 m² |
| ProPink | 8.75 | 458 mm | 3.81 m² |
| ProPink | 10.5 | 546 mm | 3.13 m² |
| Climate Pro | 7.0 | 362 mm | 4.7 m² |
| Climate Pro | 8.8 | 452 mm | 3.8 m² |
| Climate Pro | 10.5 | 543 mm | 3.2 m² |
| ThermoShield | 7.1 | 307.5 mm | 1.5 m² |
| ThermoShield | 8.8 | 384.4 mm | 1.2 m² |
| ThermoShield | 10.6 | 461.3 mm | 1.0 m² |
Sources: Owens Corning, ProPink (Canada); Johns Manville, Climate Pro (Canada); Greenfiber, ThermoShield (Canada)
Code minimums for an attic ceiling (reference)
IECC 2021, as read. States and cities adopt different editions and amendments: check your local code.
| Attic ceiling | |
|---|---|
| IECC 2021 | R-30 in climate zone 1, R-49 in zones 2 and 3, R-60 in zones 4 to 8 |
| Your climate zone | Each county's IECC 2021 zone is listed in PNNL's guide by county; the calculator never picks it for you |
| ENERGY STAR, retrofit | R-60 for an uninsulated attic, R-49 over 3 to 4 in already there, in zones 4 to 8 |
In Canada
| NBC 2020, 9.36 | Effective RSI 6.91 to 10.43, by heating degree-day zone (zones 4 to 8); the effective RSI accounts for the framing, so it is lower than the insulation's own |
|---|
Sources: DOE/PNNL, IECC 2021 R-values; PNNL, climate zone by county; ENERGY STAR, R-values; NBC 2020, 9.36 and 9.19
The R of the insulation already there (reference)
Typical values by thickness, to estimate the existing insulation from its depth. RSI = R / 5.678; the R per inch follows.
| Insulation | R per inch, about | RSI per 25.4 mm |
|---|---|---|
| Blown fiberglass | 2.6 (2.3 to 4 by product) | 0.46 |
| Poured fiberglass | 2.9 | 0.51 |
| Blown cellulose (settled depth) | 3.3 | 0.58 |
| Fiberglass batt | 3 | 0.53 |
| Mineral wool batt | 3.3 | 0.58 |
Source: NRCan, Keeping the Heat In
Before you blow: the cautions (reference)
What the sources say, as read.
| Caution | |
|---|---|
| Vermiculite | Assume it may contain asbestos and leave it undisturbed; any work that would disturb it goes to a trained asbestos professional |
| Chimneys | Keep insulation 75 mm (3 in) from chimneys |
| Wiring and lights | No insulation over knob-and-tube wiring or uncovered recessed lights |
| Soffits | At least 1 in of air between the insulation and the roof sheathing at the eave vents; insulation must not block the airflow |
| Air leaks | Seal the attic before insulating |
Sources: EPA, vermiculite; ESDC, vermiculite; NRCan, Keeping the Heat In; IRC R806.3
How it is calculated
Area = length x width, for each area. R to add = target R - existing R (zero when the existing is enough; left empty, the existing counts as zero). Bags = area / coverage per bag, the coverage read from the maker's chart at the row of the R you add, rounded up to the bag on the total. The chart's minimum thickness is shown back, the deepest one. With a product picked, the coverage and thickness come from the chart row equal to the R you add, else from the next row up, never from an interpolation; beyond the chart's last row, nothing is filled in. In feet, the calculation reads the chart's R, inch and sq ft columns; in meters, its RSI, mm and m² columns; a column the chart does not print is converted exactly (RSI = R / 5.678). With no product picked, no coverage, thickness or existing R comes filled in: they come from the bag and the attic. A chart that prints bags per 1,000 sq ft gives a coverage per bag of 1,000 / that number. Vent area = area / vent ratio (the 300 of 1/300), as in the template: the NBC asks for 1/300 of the insulated ceiling (1/150 under a slope of 1 in 6), the IRC for 1/150 of the attic (1/300 under one of its exceptions). Nothing is said about the vents already there: add up the net free area printed on each.
Example: a 1,000 sq ft attic brought to R-49
An attic 40 x 25 ft with R-11 already there, brought to R-49 (IECC 2021 in climate zones 2 and 3): R-38 to add over 1,000 sq ft. Owens Corning's AttiCat chart prints 51.4 sq ft per bag and 13 in at R-38, so 20 bags, blown to at least 13 in. Pick AttiCat in the product list and the chart fills these figures.
FAQ
How many bags of blown-in insulation do I need?
Attic area divided by the bag's coverage at the R-value you add, read from the maker's chart. A 40 x 25 ft attic (1,000 sq ft) with R-11 already there, brought to R-49, adds R-38: AttiCat's chart prints 51.4 sq ft per bag and 13 in at R-38, so 20 bags; Greenfiber INS541LD cellulose prints 16.4 sq ft and 11.97 in, so 61 bags. The chart asks for both the bag count and the thickness.
What R-value should an attic have?
IECC 2021 lists a ceiling minimum by climate zone, as read: R-30 in zone 1, R-49 in zones 2 and 3, R-60 in zones 4 to 8; PNNL's guide by county gives each county's zone. ENERGY STAR's retrofit target is R-60 for an uninsulated attic and R-49 over 3 to 4 in already there, in zones 4 to 8. States and cities adopt different editions and amendments: check your local code before the job.
How do I know the R-value already in the attic?
Measure the depth and multiply by the R per inch of what is there: about 2.6 for blown fiberglass (2.9 poured), 3.3 for blown cellulose, 3 for fiberglass batts and 3.3 for mineral wool batts (NRCan's figures, in the table below). Blown fiberglass varies a lot by product, so the result is approximate: four inches of blown fiberglass is about R-10.
Measuring a whole house for your bid?
For insulation contractors and their crews: the insulation survey takes the attic, the walls, the basement and the rim joists, the ventilation and the air sealing, each on its own line, and puts the totals by section in a PDF or Excel report for your bid. Your prices stay yours.
The whole job in MesuPro
For insulation contractors and their crews: every employee measures with the same form, the math is done as they type, and the office finds the sheet and its PDF or Excel report. 14-day free trial, no credit card.
Insulation survey
Attic, walls, foundation and rim joists: existing and target R-value, bags or units per product, vents, hazards and air sealing.
You get: Attic area Value to add Bags
All about the trade: Insulation
Your trade isn't listed? The AI assistant builds your form.
Start your 14-day free trialNo credit card. Cancel anytime.
Did this page help you?