Commercial window film

Film for multi-story buildings, floor by floor: glass area, film product and linear elements.

No credit card. Cancel anytime.

Feet and inches or metric: your choice. One switch on the sheet converts every measurement.

Commercial window film: a filled-in survey in MesuPro
Commercial window film: the same sheet on a phone
A survey made with this template, in the app.

What you measure

The template's tables and their columns, as the app shows them. Calculated columns fill in as you type.

Glass

  • Glass Width
  • Glass Height
  • Glass Surface Area calculated
  • Number of Windows
  • Total Area calculated
  • Tint SelectionChoices: Blue (code 15) Gray (code 17) Gray (code 50) Gray (code 75) Gray (code 95)
  • Film product
  • Notes
  • VLT (%)
  • Panes over 40 sq ft (3.7 m²) calculated

Frames and edges

  • Linear Length
  • Feature TypeChoices: Window Frame Edge Mullion/Divider Sill Protection Header Trim Curtain Wall Edge Storefront Edge Safety Border Decorative Trim
  • Base Material Cost per Linear Foot
  • Total Material Cost calculated
  • Base Labor Cost per Linear Foot
  • Total Labor Cost calculated
  • Total Linear Cost calculated
  • Linear Notes

See these tables calculate with your own measurements, no account.

Try this template

More templates: Windows and window film

Windows and doors: replacement measure⁠

The windows and doors of a house, room by room: replacement type, three readings with the smallest kept, squareness, depth, hinges and glass.

You get: Area

Windows: commercial building survey⁠

A window measurement template: one section per facade, one row per opening, the glazed area and perimeter per facade and for the building.

You get: Opening area Caulk perimeter

Window film⁠

Film for a house or a small building: windows, skylights and glass doors, film area per type, safety film anchoring.

You get: Total Area Panes over 40 sq ft Anchored length

About this template

Window film for multi-story commercial buildings, floor by floor.

Guide and sources

Read the guide and sources

Measure the visible glass of each pane (the daylight opening), not the window frame. The film is cut a little larger and trimmed in place, leaving a gap of about 1/16 in at the edge.

Note on each row the film product, as named on the maker's data sheet, and its VLT, the share of visible light it lets through. The area adds up per product: type it the same way on every row.

Note each pane: single or sealed unit; annealed, heat-strengthened, tempered (look for the etched mark in a corner; without one, check the glass type before installing), laminated or wired; clear, tinted or reflective; and the low-e coating, if any. Where it sits varies from window to window: check compatibility against the glass or film maker's warranty conditions.

Without the film maker's own guidance, IWFA does not recommend a solar film on an annealed sealed unit over 40 sq ft (3.7 m²) or a single annealed pane over 100 sq ft (9.3 m²). Thick, tinted or partly shaded glass also needs a suitability check before installing.

Film comes in rolls 36 to 72 in wide and 100 ft long. Warranties depend on the film and its use: follow the film maker's installation rules to keep it.

Sources

  • IWFA, safety and security guide Trade associationIWFA Safety & Security Education Guide, International Window Film Association (IWFA), 2026. Checked Oct 7, 2026
  • IWFA, visual inspection Trade associationIWFA Architectural Visual Inspection Guideline for Applied Window Film, International Window Film Association (IWFA), 2020-01-01. Checked Oct 7, 2026
  • IWFA, advanced solar guide Trade associationIWFA Advanced Solar Control Education Guide, International Window Film Association (IWFA), 2026. Checked Oct 9, 2026
  • IWFA, solar control guide Trade associationIWFA Flat Glass Solar Control Education Guide, International Window Film Association (IWFA), January 2023. Checked Oct 7, 2026
  • CPSC 16 CFR 1201 GovernmentCPSC 16 CFR 1201, Safety standard for architectural glazing materials, US Consumer Product Safety Commission, current CFR. Checked Oct 7, 2026
  • CAN/CGSB-12.1 paywalled StandardCAN/CGSB-12.1 Safety glazing, Canadian General Standards Board, 2017. Checked Nov 12, 2026

Your trade isn't listed? The AI assistant builds your form.

No credit card. Cancel anytime.