HVAC: load & duct survey

Room areas and rough loads (BTU, tonnage), design airflow, duct runs and equipment, with costs.

No credit card. Cancel anytime.

Feet and inches or metric: your choice. One switch on the sheet converts every measurement.

HVAC: load & duct survey: a filled-in survey in MesuPro
HVAC: load & duct survey: the same sheet on a phone
A survey made with this template, in the app.

What you measure

The template's tables and their columns, as the app shows them. Calculated columns fill in as you type.

Room/Area Load Calculations

  • Room Width
  • Room Length
  • Room Area calculated
  • Room typeChoices: Living Room Bedroom Kitchen Bathroom Office Conference Room Retail Floor Storage Mechanical Room Server Room Other
  • Exposed wall length
  • Window and glass door area
  • Main window orientationChoices: North East South West Several
  • Ceiling under attic or roofChoices: Yes No
  • Cooling rule of thumb (BTU/h per sq ft)
  • Cooling estimate (BTU/h) calculated
  • Heating rule of thumb (BTU/h per sq ft)
  • Heating estimate (BTU/h) calculated
  • Tonnage (sum of room peaks) calculated
  • Design airflow
  • Load Calculation Notes

Ductwork Measurements

  • Duct Length
  • Round duct diameter
  • Duct width (rectangular)
  • Duct height (rectangular)
  • Duct airflow
  • Duct velocity calculated
  • Material Cost per Linear Foot
  • Total Material Cost calculated
  • Labor Cost per Linear Foot
  • Total Labor Cost calculated
  • Total Ductwork Cost calculated
  • Ductwork Notes

Equipment & Components

  • Equipment/Component TypeChoices: Air Handler Condensing Unit Heat Pump Furnace Packaged Rooftop Unit Ductless Mini-Split ERV/HRV Exhaust Fan Electric Heat Strip Thermostat Supply diffuser/register Return Grille Damper Filter Humidifier UV Light Curb Adapter Crane Removal Line Set Condensate Pump Electrical Other
  • Size/Model
  • Capacity at design conditions
  • SEER2
  • EER2
  • HSPF2
  • AFUE
  • COP at -15 °C (5 °F)
  • Quantity
  • Unit Cost
  • Total Cost calculated
  • Installation hours (row total)
  • Equipment Notes

See these tables calculate with your own measurements, no account.

Try this template

More templates: HVAC

Ductless heat pump: installation survey⁠

A ductless heat pump, head by head: capacity, line sets and height against the manual, extra refrigerant and the outdoor unit.

You get: Line set to order

HVAC maintenance visit⁠

The maintenance visit, unit by unit: temperature rise, pressures, subcooling and superheat, filters, CO; ducts and dryer vents.

You get: Inside surface to clean

Air exchanger (HRV/ERV): installation survey⁠

An air exchanger before the work: the exhaust the code asks by bedrooms, the flows and the balance, the duct runs and the exterior hoods.

About this template

Room areas, rule-of-thumb cooling and heating estimates (BTU/h, tonnage), the design airflow, duct runs and equipment, with costs, plus ventilation, design conditions, existing equipment and utilities.

Guide and sources

Read the guide and sources

Measure each room wall to wall and note its exterior walls, its windows (area and direction) and whether its ceiling is under the attic: these are the inputs of a room-by-room load calculation, ACCA Manual J in the US or CSA F280 in Canada, which the building codes require for sizing. The BTU/h per sq ft columns are a rough estimate only: calculated loads in recent homes often run 7 to 19 BTU/h per sq ft, far below the old 25 to 35 rules.

Record the envelope (insulation, window type, air leakage from a blower door test) and, once the calculation is done, the design heat loss and gain and who calculated them. Type each room's design airflow from the designer's room-by-room report (Manual D in the US, CSA F280 in Canada): the 400 CFM per ton often quoted is a conventional figure, nearer 350 in efficient homes, and the sheet computes no airflow.

For new equipment, R-454B and R-32 are today's refrigerants; R-22 is for existing units only. Efficiency minimums are numbers: SEER2, HSPF2 and AFUE (US DOE, Canada's Energy Efficiency Regulations).

Design temperatures: pick the unit, then type the winter dry bulb and the summer dry and wet bulbs for the site. In Canada take the January 2.5 % and July 2.5 % values of the National Building Code (Division B, Appendix C), as CSA F280 does; in the US, the 99 % heating and 1 % cooling values of ACCA Manual J Table 1A or the ASHRAE Handbook. A temperature without its unit cannot be read: always choose °C or °F.

Sources

  • ACCA Manual J paywalled StandardManual J: Residential Load Calculation (ANSI/ACCA 2 Manual J-2016), ACCA, 8th edition, version 2.50 (2016). Checked Oct 7, 2026
  • ACCA, Manual J vs rules of thumb Rule of thumbManual J load calculations vs. rules of thumb (A. Bailes), ACCA HVAC blog, 2016-10-20. Checked Oct 7, 2026
  • US DOE, HVAC Equipment Sizing GovernmentStrategy Guideline: HVAC Equipment Sizing (Building America, IBACOS), US Department of Energy / NREL, 2012-02. Checked Oct 7, 2026
  • ACCA Manual D paywalled StandardManual D: Residential Duct Systems (ANSI/ACCA 1 Manual D-2016), ACCA, 3rd edition, 2016. Checked Oct 7, 2026
  • ACCA Manual S StandardManual S: Residential Equipment Selection (ANSI/ACCA Manual S-2023), ACCA, 3rd edition (2023), addenda A and B 2024. Checked Oct 7, 2026
  • 10 CFR 430.32 (US DOE) Government10 CFR 430.32 Energy conservation standards (central air conditioners, heat pumps, furnaces), US Department of Energy (eCFR), standards for units made from 2023-01-01. Checked Oct 7, 2026
  • ENERGY STAR GovernmentENERGY STAR air-source heat pumps: key product criteria, US EPA ENERGY STAR, current criteria. Checked Nov 15, 2026
  • ASHRAE 62.2 paywalled StandardASHRAE 62.2 Ventilation and Acceptable Indoor Air Quality in Residential Buildings (whole-dwelling rate, as adopted in California Mechanical Code 405), ASHRAE, 2025 (formula as adopted in CMC 405). Checked Oct 7, 2026
  • ASHRAE Handbook, climatic data paywalled StandardASHRAE Handbook, Fundamentals: Climatic Design Information, ASHRAE, 2025 ASHRAE Handbook, Fundamentals (chapter 14). Checked Nov 15, 2026
  • US EPA, HCFC phase-out GovernmentPhasing out HCFC refrigerants to protect the ozone layer, US EPA, brochure of 2015 (before the 2020 end of production). Checked Nov 15, 2026
  • US EPA, Technology Transitions GovernmentTechnology Transitions: HFC restrictions by sector (AIM Act), with the May 2026 final rule, US EPA, 2023 rule, updated May 2026. Checked Oct 7, 2026
  • US EPA, MERV GovernmentWhat is a MERV rating? US EPA, current page. Checked Nov 15, 2026
  • CSA F280-12 paywalled StandardCSA F280-12 Determining the required capacity of residential space heating and cooling appliances, CSA Group, F280-12 (reaffirmed 2021). Checked Oct 7, 2026
  • NBC 2020, 9.33 CodeNational Building Code of Canada 2020, 9.33 Heating and air-conditioning (9.33.3 design temperatures, 9.33.5.1 capacity per CSA F280), National Research Council Canada, 2020, pp. 9-223 and 9-224 (Quebec: Code de construction, chapitre I, in force 2025-04-17). Checked Nov 15, 2026
  • NRCan, heat pump sizing guide GovernmentAir-Source Heat Pump Sizing and Selection Guide, Natural Resources Canada, CanmetENERGY, version 1.0, 2020-12-21. Checked Oct 7, 2026
  • Energy Efficiency Regulations, 2016 GovernmentEnergy Efficiency Regulations, 2016 (SOR/2016-311), Government of Canada, consolidated, including SOR/2025-110. Checked Nov 15, 2026
  • NBC 2020, 9.32 CodeNational Building Code of Canada 2020, 9.32 Ventilation (Table 9.32.3.3, principal exhaust by bedrooms), National Research Council Canada, 2020 (table as printed on a 2025 municipal form). Checked Nov 11, 2026
  • ODSHAR (Canada) GovernmentOzone-depleting Substances and Halocarbon Alternatives Regulations (SOR/2016-137), Schedule 1.1, Government of Canada, current consolidation. Checked Oct 7, 2026
  • Hydro-Québec, LogisVert GovernmentLogisVert, clientèle résidentielle (aide financière pour les thermopompes), Hydro-Québec, participation guide version 1.10 (2026-09-15). Checked Oct 15, 2026
  • Quebec Construction Code, Part 11 CodeCode de construction du Québec, chapitre I, partie 11 (efficacité énergétique des petits bâtiments): ventilation with heat recovery, Régie du bâtiment du Québec (as summarised by the Municipalité des Îles-de-la-Madeleine), in force since 2012. Checked Oct 7, 2026

Your trade isn't listed? The AI assistant builds your form.

No credit card. Cancel anytime.