Siding survey
Four elevations with walls and gables, openings, trim and soffits: squares and pieces per product, housewrap, furring and old siding hazards.
No credit card. Cancel anytime.
Feet and inches or metric: your choice. One switch on the sheet converts every measurement.


What you measure
The template's tables and their columns, as the app shows them. Calculated columns fill in as you type.
Walls
- Wall
- Length
- Height
- Gable height
- Gross wall area calculated
- Openings to deduct
- Siding area calculated
- ProfileChoices: Vinyl lap Insulated vinyl Fiber-cement lap Engineered wood lap Wood lap Steel or aluminum Vertical, board and batten Shingles or shakes Panels Other
- Product
- Waste
- Squares calculated
- Exposure (shingles and shakes)
- Pieces per square
- Pieces or cartons calculated
- Membrane roll coverage
- Membrane rolls calculated
- Furring spacing
- Furring length calculated
- Crew hours
- Notes
Openings
- Opening
- TypeChoices: Window Door Garage door Other
- Width
- Height
- Count
- Opening area calculated
- Trim around calculated
- Head flashing calculated
- Notes
Trim and accessories
- Where
- ItemChoices: Starter strip J-channel Outside corner Inside corner Undersill or finish trim Drip cap or head flashing Frieze or band board Fascia Window or door trim Other
- Length
- Product
- Piece length
- Pieces calculated
- Notes
Soffits
- Location
- Length
- Depth
- Soffit area calculated
- VentedChoices: Vented Solid Mixed
- Product
- Coverage per panel or carton
- Panels or cartons calculated
- Net free area, % of the panel
- Soffit open area calculated
- Crew hours
- Notes
Attic ventilation
- Attic or roof space
- Insulated ceiling area
- Vent ratio, 1 per
- Vent area required calculated
- Share at the bottom
- Intake at the soffits calculated
- Notes
Stone veneer
- Wall
- Length
- Height
- Openings to deduct
- Outside corners, running length
- Flat area per corner length
- Flat stone area calculated
- Stone product
- Waste
- Flats coverage per box
- Boxes of flats calculated
- Corner length per box
- Boxes of corners calculated
- Lath sheet coverage
- Lath sheets calculated
- Mortar coverage per bag
- Mortar bags calculated
- Water-resistive barrier, two layers calculated
- Weep screed calculated
- Notes
Siding repairs
- Wall
- PieceChoices: Panel or board Outside corner post Inside corner post J-channel Starter strip Soffit panel Other
- ProfileChoices: Vinyl lap Insulated vinyl Fiber-cement lap Engineered wood lap Wood lap Steel or aluminum Vertical, board and batten Shingles or shakes Panels Other
- Product and color
- Pieces to replace
- Piece length
- Length to replace calculated
- MatchChoices: Matches Close match Will not match To check
- CauseChoices: Impact (hail, ball, mower) Wind Heat (grill, reflected sun) Moisture or rot Other
- Notes
See these tables calculate with your own measurements, no account.
Try this templateMore templates: Siding
Stucco repair: survey
Stucco walls by system and area, cracks, delaminated or blistered areas, moisture readings, flashings and sealant.
You get: Wall area Damaged area
About this template
Measure each elevation's walls and gables, the openings and the trim, and get the squares and pieces per product from the makers' coverage charts, with the membrane, the rainscreen furring, the soffits and the hazards of old siding.
Guide and sources
Read the guide and sources
Elevations: walk around the house with the front behind you on the left side and the right side as you face the front. On each face, measure every wall's length and height, and the gable's height from the top of the wall to the peak: a gable-end wall is one row. The siding area is the gross area, minus the openings only if you deduct them: the VSI manual says windows and doors are usually not deducted.
Material: pick the profile and name the product, then type your waste and the pieces per square from the product's coverage chart, at the exposure (reveal) and length you install. Hardie and LP publish planks or pieces per square, waste not included; the VSI manual says to add 10% to all material estimates. A square is 100 sq ft (9.29 m²). Vinyl comes in cartons: type 1 ÷ the squares per carton. The pieces are exact on each row and rounded up once per product.
Water: the cladding is the first plane of protection; a sheathing membrane or water-resistive barrier behind it is the second (NBC 9.27.3.3: one layer, laps of 100 mm; IRC R703.2: laps of 2 in, 6 in at vertical joints). Flashing goes over openings (NBC 9.27.3.8, IRC R703.4) and sealant between the siding and window and door frames (NBC 9.27.4.1).
Rainscreen: in Canada, NBC 9.27.2.2 asks a capillary break, a drained and vented space at least 9.5 mm deep, where the moisture index of Appendix C is over 0.90 (under 3400 degree-days) or 1.00 (3400 or more). It depends on the place: Montréal (0.93 at 4200) and Québec (1.0) do not need it, Sainte-Foy (1.1) and Percé (1.2) do. The IRC asks none for lap siding: follow the maker's instructions. Type the furring spacing on the wall rows that get furring.
Quebec: the Construction Code, Chapter I (the NBC 2020 modified for Quebec) applies since 2025-04-17; work begun before 2027-10-17 may still follow the previous edition (a one-year extension of the transition, in effect since 2026-09-10). Its Quebec modifications to 9.27 could not be checked here: confirm the edition and any change with the RBQ.
Clearances: the NBC keeps moisture-sensitive cladding (untreated wood, plywood, OSB, hardboard) 200 mm above the ground and 50 mm above a roof (9.27.2.4); in the US, wood siding within 6 in of the ground must be durable or treated (IRC R317.1). The makers ask their own: Hardie 6 in (203 mm in Canada) to grade and 2 in (50 mm) to roofs and decks, LP 6 in (200 mm) and 1 in (50 mm).
Old siding: asbestos-cement shingles and old fiber-cement may contain asbestos, and painted siding may carry lead paint (Health Canada: likely before 1960, possible on exteriors until 1990; US EPA RRP rule for homes built before 1978). Do not cut, sand or break a suspect material: only a laboratory test tells.
Cedar shingles: type the exposure on each wall and the cartons or bundles per square at that exposure from the maker (Maibec red cedar: 50 sq ft a carton at 7 in, 3 % added) or the CSSB coverage table (a 4-bundle square of 16 in shingles: 140 sq ft at 7 in). The exposure hint gives the NBC's and the CSSB's maxima side by side. Fascia is a trim item. Soffits: type the vented panel's net free area as a share of the panel (sq in per sq ft divided by 1.44) and the sheet gives each soffit's open area. Attic ventilation, a row per attic: the insulated ceiling area and the code's ratio (NBC 9.19.1.2: 1/300, or 1/150; IRC R806.2: 1/150, or 1/300 under its exception) give the vent area required, and the share at the bottom the intake to provide at the soffits, to compare with the soffits' open area. Never a pass or fail.
Stone veneer (adhered manufactured stone) has a section of its own, a row per wall area: the length, the height, the openings and the outside corners' running length. The flat stone area is the wall less the openings and less what the corners cover (Ply Gem: half a square foot per running foot); with your waste and each product's coverage per box, the sheet gives the boxes of flats and of corners, rounded up once per product, the lath sheets and the mortar bags. The water-resistive barrier counts two layers (CMHA, Ply Gem) and the weep screed runs along the bottom, held 4 in above the earth and 2 in above paving (IRC R703.12, CMHA).
Repairs have a section of their own, a row per kind of piece to replace on a wall: panels or boards, corner posts, J-channel, starter strip, soffit panels, with the siding type, the product and color, the pieces and their length (the length to replace adds up by piece), whether new pieces can match the old ones (asked and seen, never promised) and the cause. The hint quotes the vinyl siding manual's steps to replace a panel and repair a corner post.
Sources
- VSI installation manual Trade association
- IRC 2021, R703.11 Code
- James Hardie, HardiePlank (US) Manufacturer data
- LP SmartSide, coverage chart Manufacturer data
- Maibec, red cedar shingle Manufacturer data
- CSSB, sidewall exposure and coverage Trade association
- IRC 2021, R703.6 Code
- IRC 2021, R703.2 Code
- IRC 2021, R703.4 Code
- LP SmartSide, lap siding Manufacturer data
- IRC 2021, R317.1 Code
- CertainTeed InvisiVent soffit Manufacturer data
- IRC 2021, R806.2 Code
- Ply Gem Stone, installation guide Manufacturer data
- CMHA, adhered stone veneer guide Trade association
- IRC 2021, R703.12 Code
- VSI manual, replacing a panel Trade association
- EPA, asbestos Government
- EPA, RRP rule Government
- IRC 2021, R703.1 Code
- NBC 2020, 9.27.5.6 Code
- NBC 2020, 9.27.7 Code
- James Hardie, HardiePlank (Canada) Manufacturer data
- NBC 2020, 9.27.3.3 Code
- NBC 2020, 9.27.3.4 Code
- NBC 2020, 9.27.2.2 Code
- NBC 2020, Appendix C, Table C-2 Code
- NBC 2020, 9.27.4.1 Code
- NBC 2020, 9.27.3.8 Code
- NBC 2020, 9.27.2.4 Code
- NBC 2020, 9.19.1.2 Code
- Sakrete, stone veneer mortar Manufacturer data
- Health Canada, asbestos Government
- Health Canada, lead paint Government
- CNESST, asbestos Government
- RBQ, chapter I Government
- RBQ, transition to 2027-10-17 Government
Your trade isn't listed? The AI assistant builds your form.
No credit card. Cancel anytime.