Roofing: inspection & measurement
Face by face: area, pitch, material, condition, waste and squares, with photos, and the attic ventilation.
No credit card. Cancel anytime.
Feet and inches or metric: your choice. One switch on the sheet converts every measurement.


What you measure
The template's tables and their columns, as the app shows them. Calculated columns fill in as you type.
Roof planes
- Roof plane
- Rafter length (eave to ridge)
- Horizontal run (plan view, instead of the rafter length)
- Width along the eave
- Narrowing at the ridge (trapezoid, or the full width for a hip end)
- Pitch (X/12)
- Pitch factor calculated
- Area calculated
- Pitch rangeChoices: Flat (under 2/12) Low (2/12 to 4/12) Conventional (4/12 to 8/12) Steep (8/12 to 12/12) Very steep (over 12/12)
- MaterialChoices: 3-tab shingles (traditional) Architectural shingles (laminated) Asphalt shingles Metal Modified bitumen (SBS, 2-ply) EPDM membrane TPO membrane Membrane (EPDM/TPO) Built-up (tar and gravel) Cedar shakes Slate Other
- WorkChoices: Replace Repair No work Not in scope
- ConditionChoices: Good Fair Poor End of life Replace
- Waste
- Area with waste calculated
- Squares (100 sq ft) calculated
- Bundles per square (100 sq ft)
- Bundles calculated
- Notes
Roof lines
- Line
- Ridge and hips (length)
- Ridge cap bundle coverage
- Ridge cap bundles calculated
- Eaves (length)
- Rakes (length)
- Drip edge and rake trim (perimeter)
- Drip edge pieces (10 ft) calculated
- Starter strip (length)
- Starter bundle coverage
- Starter bundles calculated
- Eave protection depth (along the slope)
- Eave membrane roll coverage
- Eave protection area calculated
- Eave membrane rolls calculated
- Valleys (length)
- Wall and step flashing (length)
- Notes
Penetrations
- Location
- Plumbing vent boots
- Roof vents
- Chimneys
- Skylights
- Exhaust fan vents
- Notes
Attic ventilation
- Attic or roof space
- Insulated ceiling area
- Vent ratioChoices: 1/300 1/150
- Vent area at 1/300 calculated
- Vent area at 1/150 calculated
- Vent area at this ratio (net free area) calculated
- Share near the ridge
- At this ratio near the ridge calculated
- At this ratio at the soffits calculated
- Existing near the ridge
- Existing at the soffits
- Gap near the ridge calculated
- Gap at the soffits calculated
- Exhaust vent (product)
- Exhaust area per foot (ridge vent)
- Ridge vent to add calculated
- Exhaust area per vent (roof louver)
- Roof vents to add calculated
- Intake vent (product)
- Intake area per foot (continuous)
- Continuous intake to add calculated
- Intake area per vent
- Intake vents to add calculated
- Notes
See these tables calculate with your own measurements, no account.
Try this templateMore templates: Roofing
Roofing: measurement and materials
Real sloped area from the pitch, squares, shingles, underlayment, ridge cap and drip edge.
You get: Real area Area with waste Squares
Metal roofing survey
Metal roofs plane by plane: panels from the coverage width, length to order, screws, strapping, snow guards, trims and flashings.
You get: Area Panels Panel length to order
Low-slope roof survey
Flat roofs section by section: slope, system in place, test cuts, drains, upstands, rolls and boards.
You get: Area Test cuts Upstand run
About this template
Measure each roof plane along the slope or in plan view with its pitch, record material, condition and work, and get the area with waste, the squares and the shingle bundles to order, plus roof lines and penetrations. Waste covers the field shingles: starter and ridge cap come from the roof lines.
Guide and sources
Read the guide and sources
Each roof area (main roof, garage, porch) is one subsection with a tab for its planes, its lines and its penetrations: add the next one with "Add a roof area" and rename it. Measure each roof plane along the slope, or in plan view with its pitch (X in 12): the app works out the real area. Type the waste for each plane: about 10% on a gable roof and 15% on a hip roof is a trade rule of thumb, more on a cut-up roof. Starter strip, ridge cap, drip edge and eave membrane are counted in the roof lines, from the eaves and rakes you measure. The attic ventilation tab gives the net free vent area the codes ask for: type the insulated ceiling area, the ratio and the share near the ridge, then the area of the vents in place, from their labels.
A 10 ft drip edge piece covers 9 ft 10 in, because pieces lap 2 in. Asphalt shingles need at least 2/12, and from 2/12 to 4/12 the IRC asks for two underlayment layers. Where ice dams form, the ice barrier runs to at least 24 in inside the exterior wall. Bundle and roll coverage varies by product: read the wrapper.
In Quebec, the code (NBC 2020 as modified) asks for eave protection at least 900 mm up the slope and 300 mm past the inside of the wall, and the AMCQ specification asks for more: 1 m past the wall, a 4/12 minimum and underlayment over the whole roof.
The vents to add: for each attic, type the exhaust and intake products and their net free area from the maker's sheet, per foot for a ridge vent or a continuous intake (GAF Cobra ridge vents 12.5 to 18 sq in per foot, the IntakePro 9), or per vent for a roof louver or a soffit vent (GAF RV50: 50 sq in). The sheet divides the area still to vent near the ridge and at the soffits (the whole area when no existing vent is typed) and adds the feet and the vents per product, the vents rounded up once.
Sources
- IRC 2021, R905.2.2 Code
- IRC 2021, R905.1.1 Code
- Owens Corning, waste (rule of thumb) Rule of thumb
- GAF, bundles per square Manufacturer data
- Makers' data, ridge caps Manufacturer data
- IRC 2021, R905.2.8.5 Code
- Makers' data, starter strips Manufacturer data
- IRC 2021, R905.1.2 Code
- Makers' data, eave membrane Manufacturer data
- IRC 2021, R806.2 Code
- GAF, ventilation brochure (2019) Manufacturer data
- IRC 2021, R908.3 Code
- NBC 2020, Table 9.26.3.1 Code
- NBC 2020, 9.26.8 Code
- NBC 2020, 9.26.7.2 Code
- NBC 2020, 9.26.5.1 Code
- NBC 2020, 9.19.1.2 Code
- AMCQ, Division 4 (2025) Trade association
- AMCQ, bulletin 5 (2023) Trade association
Your trade isn't listed? The AI assistant builds your form.
No credit card. Cancel anytime.