Epoxy floor survey

Floor areas, joints and cracks, moisture tests, cove base, doors and drains; each coat's coverage, liquid, kits, flakes and quartz.

No credit card. Cancel anytime.

Feet and inches or metric: your choice. One switch on the sheet converts every measurement.

Epoxy floor survey: a filled-in survey in MesuPro
A survey made with this template, in the app.

What you measure

The template's tables and their columns, as the app shows them. Calculated columns fill in as you type.

Floor areas

  • Area
  • Length
  • Width
  • Deduction
  • Floor area calculated
  • ConditionChoices: Sound Oil or grease Spalls or pits Old coating to remove Hollow spots Other
  • PreparationChoices: Diamond grinding Shot blasting Scarifying Abrasive blasting Acid etching Other
  • Surface profileChoices: CSP 1 CSP 2 CSP 3 CSP 4 CSP 5 CSP 6 CSP 7 CSP 8 CSP 9 CSP 10
  • Notes

Joints and cracks

  • Location
  • TypeChoices: Control joint Expansion or isolation joint Construction joint Crack, not moving Crack, moving Spall or pit
  • Joint length
  • Width
  • Depth
  • TreatmentChoices: Fill before coating Fill after coating Keep open, flexible sealant Repair mortar Other
  • Overfill and waste
  • Filler calculated
  • Filler product
  • Package size
  • Filler packages calculated

Moisture tests

  • Location
  • TestChoices: Calcium chloride (ASTM F1869), lb per 1,000 sq ft per 24 h Relative humidity in the slab (ASTM F2170), % Plastic sheet (ASTM D4263) Moisture meter, %
  • Reading
  • Maker's limit
  • ResultChoices: Pass Fail Retest
  • Notes

Cove base

  • Wall
  • Cove length
  • Cove height
  • Wall surfaceChoices: Poured concrete Concrete block Drywall Brick Wood Other
  • Cove face calculated
  • Cove product
  • Length per kit
  • Cove kits calculated

Doors, drains and transitions

  • ItemChoices: Door or overhead door Floor drain Trench drain Column Equipment base Stairs Transition to another floor Other
  • Count
  • Item length
  • Notes

Coats

  • CoatChoices: Primer Moisture-tolerant primer Body coat Broadcast coat Grout coat Topcoat Second topcoat Self-leveling coat Other
  • Product
  • Area
  • Film thickness
  • Volume solids
  • Theoretical coverage calculated
  • Loss
  • Liquid needed calculated
  • Kit size
  • Kits calculated

Flakes and quartz

  • BroadcastChoices: Vinyl flakes Quartz Silica sand Aluminum oxide Other
  • Product
  • Area
  • Broadcast rate
  • Broadcast needed calculated
  • Box or bag
  • Boxes or bags calculated

About this template

Survey a resin floor job, garage or commercial: each space with its floor areas, joints and cracks, moisture tests against the primer's limits, cove base, doors and drains; then each coat's coverage from its film thickness and volume solids, the liquid and kits, flakes and quartz.

Guide and sources

Walk the floor with the client. Give each space its own section (the garage, the basement, a warehouse zone): measure each area to coat, less what stays bare, and note its condition, the preparation and the surface profile the coating's data sheet asks for (CSP 1 to 10, ICRI 310.2R). Note each joint and crack by type with its length, width and depth: the filler follows, and how each joint is treated depends on whether it moves.

Test the moisture before you bid: calcium chloride (ASTM F1869), relative humidity in the slab (ASTM F2170) or the plastic sheet (ASTM D4263). Compare each reading with the limit of the primer you plan: makers range from 3 lb per 1,000 sq ft per 24 h and 75% relative humidity to much more for moisture-tolerant primers. Check that the slab is at least 3 °C (5 °F) above the dew point. Measure the cove base by wall at its height, and count the doors, drains and transitions.

Under Coating system, one row per coat: its product, area, film thickness and volume solids give its coverage (1,604 sq ft per gallon at 1 mil for 100% solids), your loss gives the liquid, the kit size the kits, rounded up once per product. Flakes and quartz follow from the area, your broadcast rate and the box size. Nothing is pre-filled: every limit, thickness, rate and kit comes from the data sheet of the product you choose.

Sources

  • Sherwin-Williams site survey Manufacturer dataArea Site Survey (High Performance Flooring), Sherwin-Williams, PM-561548 03/26. Checked Oct 12, 2026
  • ICRI 310.2R paywalled Trade associationSelecting and Specifying Concrete Surface Preparation for Sealers, Coatings, Polymer Overlays, and Concrete Repair (Guideline 310.2R), International Concrete Repair Institute, 2013. Checked Oct 12, 2026
  • Graco CSP chart Manufacturer dataConcrete Surface Prep Part 3: Grades of Roughness, Graco, undated (read 2026-10-12). Checked Oct 12, 2026
  • Rio-Coat EHB Manufacturer dataRio-Coat EHB Technical Data Sheet, Rio Flooring Systems, TDS of 2026-09-18 (ARCAT copy). Checked Oct 12, 2026
  • Sherwin-Williams joint guide Manufacturer dataJoint Guidelines (resin flooring), Sherwin-Williams, undated (PDF of 2026-07). Checked Oct 12, 2026
  • Euclid QWIKjoint UVR 95 Manufacturer dataEuco QWIKjoint UVR 95, technical data sheet, Euclid Chemical, Rev. 02.26. Checked Oct 12, 2026
  • ASTM F1869 paywalled StandardASTM F1869, Standard Test Method for Measuring Moisture Vapor Emission Rate of Concrete Subfloor Using Anhydrous Calcium Chloride, ASTM International, F1869-23. Checked Oct 12, 2026
  • ASTM F2170 paywalled StandardASTM F2170, Standard Test Method for Determining Relative Humidity in Concrete Floor Slabs Using in situ Probes, ASTM International, F2170-19a. Checked Oct 12, 2026
  • ASTM D4263 paywalled StandardASTM D4263, Standard Practice for Indicating Moisture in Concrete by the Plastic Sheet Method, ASTM International, D4263-24. Checked Oct 12, 2026
  • Sherwin-Williams G-1 Manufacturer dataConcrete Surface Preparation Guide G-1 (resin flooring), Sherwin-Williams, 02/26. Checked Oct 12, 2026
  • Tnemec Series 1418 Manufacturer dataSeries 1418 Vinester 60 Mil Broadcast, application guide, Tnemec, 09/2020. Checked Oct 12, 2026
  • Simiron cove kit Manufacturer dataEpoxy Cove Base Kit, product data sheet, Simiron, 11/12/2025. Checked Oct 12, 2026
  • General Polymers cove base Manufacturer dataEpoxy Cove Base System (General Polymers), Sherwin-Williams (General Polymers), 2017. Checked Oct 12, 2026
  • Rust-Oleum OverKrete cove Manufacturer data8600 System OverKrete 45/65 CB, heavy-duty epoxy cove base, technical data, Rust-Oleum (copy hosted on testors.com), undated (read 2026-10-12). Checked Oct 12, 2026
  • Sherwin-Williams Deco Flake DB Manufacturer dataResuflor Deco Flake DB System, application instructions, Sherwin-Williams, 12-20-24. Checked Oct 12, 2026
  • PPG data sheet explanation Manufacturer dataExplanation to Product Data Sheets, PPG, January 2024. Checked Oct 12, 2026
  • Spartan mil bulletin Manufacturer dataConcrete Evidence Info/Tech Bulletin: Mil Thickness, Spartan Chemical, SCC 3/09. Checked Oct 12, 2026
  • Rust-Oleum EpoxyShield Manufacturer dataEpoxyShield Water-Based Garage Floor Coating, technical data, Rust-Oleum (copy hosted by a retailer), GDH-356 Rev. 012915. Checked Oct 12, 2026
  • Miracote MiraFlor Flake Manufacturer dataMiraFlor Flake Full Broadcast system, installation guide, Crossfield Products (Miracote), Rev. 04/20. Checked Oct 12, 2026
  • Resinwerks KTX-F Manufacturer dataKTX-F flake system, technical data sheet, Resinwerks, 2024. Checked Oct 12, 2026
  • Laticrete Spartacote Flex SB 250 Manufacturer dataSPARTACOTE FLEX SB 250, data sheet, Laticrete, DS-36627-0226. Checked Oct 12, 2026
  • 40 CFR 59 subpart D GovernmentNational Volatile Organic Compound Emission Standards for Architectural Coatings, 40 CFR Part 59 Subpart D, US Environmental Protection Agency (eCFR), eCFR, read 2026-10-12. Checked Oct 12, 2026
  • SCAQMD Rule 1113 GovernmentRule 1113, Architectural Coatings, South Coast Air Quality Management District, amended 2016-02-05. Checked Oct 12, 2026
  • Mapei Mapefloor manual Manufacturer dataMapefloor resinous flooring systems: installation manual (French edition), Mapei Canada, 2020. Checked Oct 12, 2026
  • Sika epoxy guide Manufacturer dataSikafloor Epoxy Coating Application Guide, Sika Canada, 03.2021/v1. Checked Oct 12, 2026
  • MF Paints MF26xx Manufacturer dataMF2653 / MF2673 / MF2683 100 % solids epoxy, technical data sheet, MF Paints (Peintures MF, Laval), rev. 2017-04-06. Checked Oct 12, 2026
  • Sikafloor-261 CA Manufacturer dataSikafloor-261 CA Product Data Sheet, Sika Canada, June 2026, version 01.04. Checked Oct 12, 2026
  • Sika cove mortar Manufacturer dataSikafloor Morritex Epoxy Cove Mortar system, product data sheet (French), Sika Canada, 06.2018. Checked Oct 12, 2026
  • Sikafloor-156 CA Manufacturer dataSikafloor-156 CA Product Data Sheet, Sika Canada, June 2026, version 01.04. Checked Oct 12, 2026
  • Sika garage kit Manufacturer dataSikafloor-200 Garage Epoxy Kit, instruction sheet (French), Sika Canada, 2023. Checked Oct 12, 2026
  • SOR/2009-264 GovernmentVolatile Organic Compound (VOC) Concentration Limits for Architectural Coatings Regulations (SOR/2009-264), Government of Canada (Justice Laws), current to 2026-09-21, last amended 2019-06-17. Checked Oct 12, 2026

More templates: Epoxy floors

Polished concrete survey

Ground and polished concrete: exposure class, appearance level, steps, hours, densifier, guard, DOI, gloss and haze readings.

You get: Floor to polish

Your trade isn't listed? The AI assistant builds your form.

Start your 14-day free trial

No credit card. Cancel anytime.