Commercial painting

Commercial areas with deductions, primer and finish coats, gallons to order and trim costs per linear foot.

No credit card. Cancel anytime.

Feet and inches or metric: your choice. One switch on the sheet converts every measurement.

Commercial painting: a filled-in survey in MesuPro
Commercial painting: the same sheet on a phone
A survey made with this template, in the app.

Commercial painting: an office floor (3 min 32 s)

What the video says

An office floor: partitions on both sides, three kinds of ceiling, openings to deduct. Measured after hours, desks empty. On the sheet: Extended hours. The first office, wall by wall: the exterior wall first, with its window. The window is deducted: 20 sq ft. That leaves 70 sq ft of net paintable area. A partition gets painted on both sides: each face has its own row, in the room it is painted from. The T-bar ceiling: not painted, not counted, but noted on the sheet. This office is measured, and the other offices on this floor are the same. 4 identical offices: measure one. 1,420 sq ft of walls for all of them: measure one office, type 4, and the totals count them all. The corridor: one row per side, with each side's openings deducted on that same row. North side, in Deductions: 5 times 21 for the doors, plus 162 for the storefront. The sheet keeps 267 sq ft. The gypsum ceiling gets painted, flat, in the Ceilings tab. The stair door: the steel frame and door get painted, and the fire label on the hinge jamb gets masked. On the stair door's row, the Fire label column says Label to mask: the crew masks it before painting. The open office: no T-bar ceiling, the deck stays exposed. Here the walls go up to the deck: 13 ft. The café partition has a wide opening, with no door. The opening to the café is deducted: 250 sq ft. Overhead, in the Ceilings tab: the fluted steel deck, typed as Exposed deck. The fluted deck unfolds: 1.4 times the floor area. Joists count as solid, both faces: spraying an open web wastes a lot of paint. 3,042.6 sq ft overhead, in dry-fall, deck and joists included. The café's accent wall gets its own product, muted teal: its gallons come out on a line of their own, apart from the off-white. The ducts, by the linear foot: 44 inches of girth, in the same black. Type the length, and the sheet turns it into square feet. The café duct goes on its own row, with the same girth and the same black, at its own length. 59.5 ft of ducts, or 218.17 sq ft. Back to the floor, then the totals for the whole sheet, product by product. Every steel frame is counted: 8 on the floor. Eggshell off-white: 25 gal. Teal: 2 gal. Dry-fall for the ducts: 1 gal. The frames, direct to metal: 2 gal. Dry-fall: 19 gal overhead. Flat white: 2 gal. Each product is rounded up once, and the Containers line says what to buy. The PDF and the Excel file, for your own estimate. Try MesuPro free for 14 days.

The same template, with your own measurements.

Try this template

What you measure

The template's tables and their columns, as the app shows them. Calculated columns fill in as you type.

Commercial Surface Area Calculations

  • Width
  • Height
  • Gross Surface Area calculated
  • Deductions (doors, windows, fixtures)
  • Net Paintable Area calculated
  • Calculate AsChoices: + Add to Total - Subtract from Total
  • Primer Coats
  • Finish Coats
  • Area to cover, primer and finish coats calculated
  • Primer Gallons Needed calculated
  • Finish Paint Gallons Needed calculated
  • Surface TypeChoices: Drywall - Smooth Drywall - Textured Plaster Wood Metal Masonry Concrete
  • Paint TypeChoices: Latex - Flat Latex - Eggshell Latex - Satin Latex - Semi-Gloss Latex - Gloss Oil-Based Epoxy Specialty
  • Finish code
  • MPI systemChoices: INT 9.2A Latex over latex primer-sealer (gypsum board) INT 9.2B High performance architectural latex (gypsum board) INT 9.2M Institutional low odor/VOC (gypsum board) INT 9.2E Epoxy, tile-like (gypsum board) INT 4.2A Latex over latex block filler (concrete block) INT 4.2D High performance architectural latex over latex block filler (concrete block) INT 4.2E Institutional low odor/VOC over latex block filler (concrete block) INT 4.2F Epoxy over latex block filler, dry areas (concrete block) INT 4.2G Epoxy over epoxy block filler, wet areas (concrete block) INT 3.1A Latex over alkali-resistant primer (concrete) INT 5.1B Water-based light industrial coating over rust-inhibitive primer (steel) INT 5.3J Latex over galvanized primer (galvanized metal) Other
  • Paint (product, color)
  • Primer (product)
  • Area Notes
  • Finish Spread Rate (from the can)
  • Primer Spread Rate (from the can)

Doors and frames

  • Where
  • DoorChoices: Interior door Exterior door Closet or bifold door Hollow metal door Other
  • Doors (each)
  • Door width
  • Door height
  • Sides painted
  • Door area calculated
  • Frames (each)
  • Area of one frame
  • Frame area calculated
  • Doors and frames to paint calculated
  • Primer Coats
  • Finish Coats
  • Primer Spread Rate (from the can)
  • Finish Spread Rate (from the can)
  • Paint (product, color)
  • Primer (product)
  • Finish Paint Gallons Needed calculated
  • Primer Gallons Needed calculated
  • Fire labelChoices: No label Label to mask
  • Area Notes

Ceilings

  • Where
  • Ceiling typeChoices: Painted gypsum Exposed deck T-bar (not painted) Other
  • Length
  • Width
  • Plan area calculated
  • Deck factor (unfolded / plan)
  • Ceiling to paint calculated
  • Joists (each)
  • Joist length
  • Joist depth
  • Sides painted
  • Joists, measured solid calculated
  • Ceiling and joists to paint calculated
  • Primer Coats
  • Finish Coats
  • Primer Spread Rate (from the can)
  • Finish Spread Rate (from the can)
  • Paint (product, color)
  • Primer (product)
  • Finish Paint Gallons Needed calculated
  • Primer Gallons Needed calculated
  • Area Notes

Wallcovering

  • Where
  • Wallcovering code
  • Wallcovering (maker, pattern, color)
  • Type (weight)Choices: Type I Type II Type III Other
  • Width
  • Height
  • Openings left out
  • Net wallcovering area calculated
  • Goods width
  • Pattern repeat
  • MatchChoices: Free match Straight match Offset match Other
  • Trim allowance
  • Bolt length
  • Strips calculated
  • Strip length calculated
  • Linear yards calculated
  • Bolts calculated
  • Area Notes

Commercial Linear Measurements

  • Linear Length
  • Feature TypeChoices: Trim - Standard Trim - Decorative Handrail Pipe/Conduit Structural Steel Storefront Window Frames Door Frames Safety Markings
  • Girth (around the piece)
  • Area to paint, at least 1 ft wide calculated
  • Paint area (girth as typed) calculated
  • Primer Coats
  • Finish Coats
  • Area to cover, primer and finish coats calculated
  • Primer Gallons Needed calculated
  • Finish Paint Gallons Needed calculated
  • Paint (product, color)
  • Primer (product)
  • Finish Spread Rate (from the can)
  • Primer Spread Rate (from the can)
  • Linear Notes
  • Material Cost per Linear Foot
  • Total Material Cost calculated
  • Labor Cost per Linear Foot
  • Total Labor Cost calculated
  • Total Linear Cost calculated

See these tables calculate with your own measurements, no account.

Try this template

More templates: Painting

Residential painting⁠

Room by room: walls (a whole room on one line), ceilings, trim, doors and cabinets, with gallons and labor hours.

You get: Net Paintable Area Area to cover, primer and paint coats Paint

Exterior painting and staining survey⁠

Elevation by elevation: walls and gables, trim, soffits, doors and shutters, decks and fences to stain, gallons per product.

You get: Area to paint Paint Trim area

Wallpaper: installation survey⁠

Wall by wall: the drops, the drop length rounded up to the pattern repeat, the drops per roll and the rolls per wallpaper.

You get: Wall area Rolls

About this template

Commercial surfaces with deductions, primer and finish coats, and the gallons of paint to order.

Guide and sources

Read the guide and sources

Measure each surface, width by height, and type in Deductions every opening that is not painted: a door is about 21 sq ft (3 x 7 ft), a window or a storefront counts as measured. The gallons come from this net area. If you price labor per square foot to PCA standard P10, it deducts only the openings of 100 sq ft or more, and those that run floor to ceiling and are wider than 5 ft: the Gross Surface Area column (width x height) gives that area when no opening reaches 100 sq ft.

Coats follow the specified MPI system: premium grade is one primer and two finish coats, custom grade one and one.

The gallons use the spread rate on your product's data sheet, typed in each row for the finish and for the primer: a block filler on concrete block and a masonry primer cover far less than a drywall primer, so type what their data sheet prints. Empty: 400 sq ft/gal (9.8 m²/L) is used for the finish and 350 (8.6 m²/L) for the primer, the columns' defaults and the low ends the cited data sheets print. Each result is approximate: real use varies with the surface's porosity and texture, the color change, the application method and the losses, which no data sheet includes.

Rate the existing paint by MPI degree of surface degradation, from DSD-0 (sound) to DSD-4 (substrate damage), and note the year built for lead paint.

Identical rooms: measure one typical room (a hotel's King room, a floor's identical units) and type how many are like it in "Rooms like this one". The rows keep that one room's measurements; the area's totals, its gallons and the sheet's totals count them all, each product rounded up once on the whole. A room that differs (a suite, a corner unit) gets its own area.

Doors and frames: a tab in each area, so an area's "Rooms like this one" counts its doors too. Count the doors each with their size and the sides painted, the frames apart with an area each (the frame's length times its girth, at least 1 ft wide, PCA P10 5.1 and 5.2). Hollow metal takes a direct-to-metal coating at the spread rate its data sheet prints. Mark the fire-rated doors and frames: their label is masked, never painted (NFPA 80).

Linear elements (handrails, exposed pipe and conduit, steel, frames): measure the length and the girth, the width painted around the piece. The area counts at least 1 ft wide (PCA P10 5.1 and 5.2), and its coats, products and gallons work as on the surfaces, so the job's totals per product include them.

Ceilings: a tab in each area, so its "Rooms like this one" counts them too. Name the type: a T-bar ceiling is not painted and not counted; painted gypsum counts its plan area; an exposed deck counts its plan area times the deck factor you measure on its profile (PCA P10 5.6), plus its open-web joists measured as solid, on one or both faces (5.7). Its gallons show per product in the tab's own columns.

Wallcovering: a tab in each area for commercial vinyl, one row per wall. Give each wall its code from the finish schedule (WC-1), the goods width (54 in), the pattern repeat and the bolt length from the label: the strips are counted on the wall's full width, each cut to whole repeats plus the trim allowance, and the linear yards and bolts add up per code. A new gypsum wall takes a pigmented primer first (Wolf-Gordon): count it in the surfaces tab.

Sources

  • Wallcoverings Association, W-101 Trade associationW-101, WA Quality Standard for Polymer Coated Fabric Wallcovering, Wallcoverings Association, 2025. Checked Nov 1, 2026
  • Koroseal, KoroGraphics Manufacturer dataKoroGraphics digital wallcovering, fact sheet, Koroseal Interior Products, fact sheet read 2026-11-01. Checked Nov 1, 2026
  • Astek, square footage conversions Manufacturer dataAstek Square Footage Conversions, Astek Wallcovering, PDF read 2026-11-01. Checked Nov 1, 2026
  • Wolf-Gordon, vinyl installation Manufacturer dataWolf-Gordon, vinyl wallcovering installation instructions, Wolf-Gordon, PDF read 2026-11-01. Checked Nov 1, 2026
  • PCA P10 Trade associationPCA P10, Measurement of Surface Area for Estimating Painting and Decorating Work, Painting Contractors Association (PCA), PCA Industry Standards, 2023-09-18, pp. 49 to 51. Checked Oct 31, 2026
  • MPI 09 91 23 Trade associationMPI Architectural Painting Manual, guide specification 09 91 23 Interior Painting, Master Painters Institute (MPI), Rev. April 2022. Checked Oct 7, 2026
  • Benjamin Moore, 253 Manufacturer dataBenjamin Moore Super Spec Latex Enamel Undercoater and Primer Sealer 253, technical data sheet, Benjamin Moore, 2018-06-18. Checked Oct 7, 2026
  • Sherwin-Williams, ProMar 200 primer Manufacturer dataSherwin-Williams ProMar 200 Zero VOC Interior Latex Primer, product data sheet, Sherwin-Williams, 108.24A (2/2025). Checked Nov 12, 2026
  • Zinsser, Bulls Eye 1-2-3 Manufacturer dataZinsser Bulls Eye 1-2-3 primer, technical data sheet, Rust-Oleum (Zinsser), BEY123-01. Checked Oct 7, 2026
  • Coronado (Benjamin Moore), Dry Fall N110 Manufacturer dataDry Fall Acrylic Latex Flat N110, technical data sheet, Coronado Paint, Benjamin Moore & Co. N110 US 112823. Checked Oct 31, 2026
  • Behr, paint quantity guide Rule of thumbBehr, How much exterior paint to buy, Behr, online guide. Checked Nov 11, 2026
  • Sherwin-Williams, Pro Industrial DTM Manufacturer dataPro Industrial DTM Acrylic Semi-Gloss, B66-1150 series, product data sheet 113.07A, Sherwin-Williams, 10/2022. Checked Oct 31, 2026
  • Benjamin Moore, Ultra Spec HP DTM Manufacturer dataUltra Spec HP D.T.M. Acrylic Semi-Gloss (FP29), technical data sheet, Benjamin Moore, Canadian data sheet. Checked Oct 31, 2026
  • iDigHardware, NFPA 80 labels StandardFire door assembly inspection criteria and painted labels (NFPA 80, as quoted by iDigHardware), Allegion, iDigHardware (L. Greene, M. Latham), Articles of 2023-03-07 and 2025-10-13. Checked Oct 31, 2026
  • Benjamin Moore, F547 Manufacturer dataBenjamin Moore Regal Select Interior Flat F547, product specifications, Benjamin Moore, en-ca product page. Checked Nov 11, 2026
  • EPA RRP, 40 CFR 745 GovernmentLead Renovation, Repair and Painting rule, 40 CFR 745 subpart E, US Environmental Protection Agency, current CFR. Checked Oct 7, 2026
  • NBC 2015, 3.1.8.5 (intent) CodeNational Building Code of Canada 2015, intent of Sentence 3.1.8.5.(2), closures in fire separations, National Research Council Canada, 2015 intent statements. Checked Nov 11, 2026
  • Sico, data sheet 861-113 Manufacturer dataFiche technique Sico Évolution 861-113, Sico (PPG Canada), 2016-06-10. Checked Oct 7, 2026
  • Dulux, data sheet 41220 Manufacturer dataFiche technique Dulux Diamant Distinction 41220 (perle), Dulux (PPG Canada), online data sheet. Checked Oct 7, 2026
  • Benjamin Moore, Latex Block Filler K160 Manufacturer dataSuper Spec Latex Block Filler (K160), technical data sheet, Benjamin Moore & Co., Limited, Canadian data sheet M72 K160 CE 060611. Checked Oct 31, 2026
  • Health Canada, lead paint GovernmentHealth Canada, Lead-based paint, Health Canada, modified 2026-10-02. Checked Oct 7, 2026

Your trade isn't listed? The AI assistant builds your form.

No credit card. Cancel anytime.