Drywall survey
Walls and ceilings room by room, sheets per product, corners and trim, compound, tape and screws, level of finish and fire separation.
No credit card. Cancel anytime.
Feet and inches by default, metric available for each table.

What you measure
The template's tables and their columns, as the app shows them. Calculated columns fill in as you type.
Walls and ceilings
- SurfaceChoices: Wall Ceiling Bulkhead or soffit Other
- Where
- Length
- Height or width
- Openings to deduct
- Board area calculated
- Board typeChoices: Regular Moisture-resistant Type X (fire-rated) Abuse-resistant Glass-mat tile backer Other
- ThicknessChoices: 9.5 mm (3/8 in) 12.7 mm (1/2 in) 15.9 mm (5/8 in) Other
- Product
- Sheet width
- Sheet length
- Waste
- Sheets calculated
- Crew hours
- Notes
Corners and trim
- ItemChoices: Outside corner bead L or J trim Control joint Other
- Where
- Trim length
- Product
- Piece length
- Trim pieces calculated
- Notes
Finishing materials
- Where
- Board area to finish
- Compound product
- Compound per area
- Compound calculated
- Tape per area
- Tape calculated
- Screws per area
- Screws calculated
- Notes
About this template
Measure the walls and ceilings of each room, get the sheets per product, the corners and trim, and the compound, tape and screws for the job from the makers' per-area rates, with the board type, level of finish and fire separation each room needs.
Guide and sources
Rooms: measure each room on the floor, one row per wall and one per ceiling: a wall's length and height, a ceiling's length and width. "Add a room" adds the next one with its tables blank; "Add a section like this one" adds the next floor. Deducting openings is your call: CGC and CertainTeed count them as board, USG subtracts only the large ones.
Board: pick the type and thickness the spacing and the room ask for. NBC Table 9.29.5.3 and IRC Table R702.3.5 give the thickness by support spacing; Type X is the fire-rated core; moisture-resistant board is not for wet areas or directly behind tile in a shower, and tile around tubs and showers goes over a moisture-resistant backing (NBC 9.29.10.4, IRC R702.3.7). Type the sheet size from the product's data sheet and your waste: no maker publishes a waste figure. The sheets are exact on each row and rounded up once per product.
Fire separation: in Canada a house's own garage needs no fire separation, only an air barrier against fumes (NBC 9.10.9.18); suites are separated by 45 min, or by 12.7 mm board where a secondary suite allows it (9.10.9.16; Quebec limits that option to 3 units and 2 storeys). Table 9.10.3.1.-A rates stud walls (12.7 mm Type X one layer each side: 45 min). In the US, the garage side gets 1/2 in board and a ceiling under rooms 5/8 in Type X (IRC R302.6); an enclosed space under stairs 1/2 in (R302.7).
Finishing: in the Finishing section, type the board area once (the rooms' total, shown in the totals) and the rates from the data sheets: compound about 10 gal per 1,000 sq ft (USG; CGC prints 40.5 L/100 m²), paper tape about 370 ft per 1,000 sq ft, screws from the maker's tables (about 1,000 per 1,000 sq ft at 16 in framing). Beware of "per 100 m²" columns that repeat the per-1,000 sq ft numbers. The level of finish (GA-214, 0 to 5) sets how many coats go on. Fasteners follow NBC 9.29.5.8 and 9.29.5.9, IRC Table R702.3.5 and GA-216; ASTM C840 is the application standard.
Quebec: the Construction Code, Chapter I (the NBC 2020 modified for Quebec) applies since 2025-04-17; work begun before 2027-10-17 may still follow the previous edition. Its Quebec changes leave 9.29 as is and limit 9.10.9.16. In cold weather keep the space at 10 °C or more for 48 h before and after taping (NBC 9.29.5.10).
Older homes: Health Canada lists paint, putty, drywall, caulking, sealants and spackling among older materials that may contain asbestos, and lead paint is likely before 1960 (possible until 1990; the US EPA RRP rule covers homes built before 1978). Do not sand or break a suspect surface: only a laboratory test tells.
Sources
- CertainTeed, installation guide Manufacturer data
- USG, installation guide Manufacturer data
- GA-223 Trade association
- IRC 2021, R702.3.7 Code
- National Gypsum, construction guide Manufacturer data
- IRC 2021, R702.3.5 Code
- GA-216 Trade association
- USG, all purpose compound Manufacturer data
- USG, paper joint tape Manufacturer data
- ASTM C840 paywalled Standard
- GA-214 Trade association
- IRC 2021, R302.6 Code
- IRC 2021, R302.7 Code
- EPA, RRP rule Government
- CGC handbook Manufacturer data
- NBC 2020, Table 9.10.3.1.-A Code
- NBC 2020, 9.29.10.4 Code
- CertainTeed, M2Tech Manufacturer data
- NBC 2020, 9.29.5.3 Code
- CGC, all purpose compound Manufacturer data
- CertainTeed, ready-mix compounds Manufacturer data
- NBC 2020, 9.29.5.9 Code
- NBC 2020, 9.29.2.1 Code
- NBC 2020, 9.10.9.18 Code
- NBC 2020, 9.10.9.16 Code
- Health Canada, asbestos Government
- Health Canada, lead paint Government
- NBC 2020, 9.29.5.10 Code
- RBQ, chapter I Government