How to measure an attic for insulation
Before you bid, go up into the attic: its area, the insulation already there and its depth, the ventilation and the air leaks. A worked example and a free calculator are waiting at the end.
What to bring
- A headlamp and a respirator
- A tape measure and a ruler for the insulation depth
- Boards to walk across the joists
- Your phone to record and photograph each area in a MesuPro survey
If you see vermiculite, leave it undisturbed: assume it may contain asbestos, and leave any work that would disturb it to a trained asbestos professional. Step on the joists, never between them.
Step by step
Measure the attic floor, area by area
Length x width of each area, at joist level, from one exterior wall's top plate to the other. Start a new area wherever the ceiling changes level, an addition begins or the insulation already there changes: each one gets its own row. No safe way across the attic? Add up the ceilings of the rooms below, closets and hallways included: the total comes out a little smaller than the attic floor, by the thickness of the walls.
Find the insulation already there and its depth
Slide a ruler down to the ceiling board without packing the insulation, in at least three spots per area: by the hatch, in the middle and toward the eaves, where the layer is usually thinnest. Note the type: loose fiberglass (pink, yellow or white fluff), cellulose (gray shredded paper), batts or rock wool. Gray-brown or gold pebbles are probably vermiculite: stop there and read the safety note.
Turn that depth into an R-value
Multiply the depth by the R per inch of the material (the table below, from Natural Resources Canada): 4 in of blown fiberglass is about R-10, 4 in of cellulose about R-13. A layer that is packed down, damp or disturbed gives less, so round down when in doubt. In metric, RSI = R / 5.678.
Choose the target, then the R to add
The IECC 2021 sets R-49 for a ceiling in climate zone 3 and R-60 in zones 4 to 8. ENERGY STAR suggests R-60 for an empty attic in zones 4 to 8, or R-49 on top of 3 to 4 in already there. In Canada, the NBC 2020 sets an effective RSI by heating degree-day zone, and Quebec applies it through Part 11 of its Construction Code. Programs such as Rénoclimat and LogisVert have their own requirements. R to add = target - existing, area by area.
Read the bag chart at the right row
Every bag prints a chart by R-value: the minimum thickness, the coverage per bag or the bags per 1,000 sq ft, and often a minimum weight per square foot. Use the row equal to the R you add or the next one up, never a value between two rows. A chart that prints 34 bags per 1,000 sq ft gives 1,000 / 34 = 29.4 sq ft per bag: a 1,120 sq ft ceiling takes 38.1 bags, so 39. The chart asks for both numbers: the full bag count and the minimum thickness everywhere.
Count the baffles and the vents
Each rafter bay with a soffit vent needs a baffle so the insulation never blocks the air: the IRC keeps at least 1 in of air at the vents, the NBC 63 mm above the insulation. Count the bays along each eave. Then add up the net free area printed on every soffit and roof vent. The NBC asks for at least 1/300 of the insulated ceiling area (1/150 under a slope of 1 in 6), at least a quarter high and a quarter low; the IRC asks for 1/150 of the attic, or 1/300 under one of its exceptions.
Note the air leaks and the clearances
Seal before you blow: the hatch, the top plates, the holes for pipes and wires, the chimney chase. Keep insulation 3 in (75 mm) away from chimneys, off knob-and-tube wiring and off recessed lights that are not covered. Photograph each spot: it goes in the survey and in the report to the client.
Depth to R-value: blown insulation (reference)
Approximate values for loose fill in good condition: the depth times the R per inch Natural Resources Canada gives, about R-2.6 for blown fiberglass and R-3.3 for blown cellulose (settled depth), rounded. Blown fiberglass varies a lot by product (R-2.3 to R-4 per inch); damp, compressed or disturbed insulation gives less.
| Depth | Blown fiberglass | Blown cellulose |
|---|---|---|
| 4 in | R-10 | R-13 |
| 6 in | R-16 | R-20 |
| 8 in | R-21 | R-26 |
| 10 in | R-26 | R-33 |
| 12 in | R-31 | R-40 |
| 16 in | R-42 | R-53 |
| 20 in | R-52 | R-66 |
Source: NRCan, Keeping the Heat In
The calculation
Area = length x width, for each area. R to add = target R - existing R (zero when the existing is enough; left empty, the existing counts as zero). Bags = area / coverage per bag, the coverage read from the maker's chart at the row of the R you add, rounded up to the bag on the total. The chart's minimum thickness is shown back, the deepest one. With a product picked, the coverage and thickness come from the chart row equal to the R you add, else from the next row up, never from an interpolation; beyond the chart's last row, nothing is filled in. In feet, the calculation reads the chart's R, inch and sq ft columns; in meters, its RSI, mm and m² columns; a column the chart does not print is converted exactly (RSI = R / 5.678). With no product picked, no coverage, thickness or existing R comes filled in: they come from the bag and the attic. A chart that prints bags per 1,000 sq ft gives a coverage per bag of 1,000 / that number. Vent area = area / vent ratio (the 300 of 1/300), as in the template: the NBC asks for 1/300 of the insulated ceiling (1/150 under a slope of 1 in 6), the IRC for 1/150 of the attic (1/300 under one of its exceptions). Nothing is said about the vents already there: add up the net free area printed on each.
Worked example
In the fictitious two-story house of the demo "Insulation - Two-story house, Columbus OH", climate zone 5A, the main attic of 40 ft by 28 ft has blown fiberglass at R-11, and the bonus room attic of 12 ft by 20 ft has none. To reach R-60, the main attic needs R-49 more and the bonus room R-60, over 1,360 sq ft in all. The maker's chart gives 38.8 sq ft per bag at its R-49 row for the main attic and 31.1 sq ft at its R-60 row for the bonus room: 37 bags in all, blown to at least 20 in (16.5 in over the main attic). With the IRC's 1/150, the attic needs 1,305.6 sq in of net free vent area.
Common mistakes
- Counting bags without checking the thickness, or the reverse: the chart requires both.
- Adding up the bags of two different products.
- Reading the chart at the target instead of the R you add, or between two rows.
- Measuring the depth by the hatch only: the eaves are usually thinner.
- Blocking the soffits: without baffles, the attic no longer breathes.
- Blowing before sealing the air leaks at the hatch, top plates and penetrations.

The whole job in MesuPro
Insulation survey
Attic, walls, foundation and rim joists: existing and target R-value, bags or units per product, vents, hazards and air sealing.
You get: Attic area Value to add Bags
Your trade isn't listed? The AI assistant builds your form.