Drywall survey

Walls and ceilings room by room, sheets per product, corners and trim, compound, tape and screws, level of finish and fire separation.

No credit card. Cancel anytime.

Feet and inches by default, metric available for each table.

Drywall survey: a filled-in survey in MesuPro
A survey made with this template, in the app.

What you measure

The template's tables and their columns, as the app shows them. Calculated columns fill in as you type.

Walls and ceilings

  • SurfaceChoices: Wall Ceiling Bulkhead or soffit Other
  • Where
  • Length
  • Height or width
  • Openings to deduct
  • Board area calculated
  • Board typeChoices: Regular Moisture-resistant Type X (fire-rated) Abuse-resistant Glass-mat tile backer Other
  • ThicknessChoices: 9.5 mm (3/8 in) 12.7 mm (1/2 in) 15.9 mm (5/8 in) Other
  • Product
  • Sheet width
  • Sheet length
  • Waste
  • Sheets calculated
  • Crew hours
  • Notes

Corners and trim

  • ItemChoices: Outside corner bead L or J trim Control joint Other
  • Where
  • Trim length
  • Product
  • Piece length
  • Trim pieces calculated
  • Notes

Finishing materials

  • Where
  • Board area to finish
  • Compound product
  • Compound per area
  • Compound calculated
  • Tape per area
  • Tape calculated
  • Screws per area
  • Screws calculated
  • Notes

About this template

Measure the walls and ceilings of each room, get the sheets per product, the corners and trim, and the compound, tape and screws for the job from the makers' per-area rates, with the board type, level of finish and fire separation each room needs.

Guide and sources

Rooms: measure each room on the floor, one row per wall and one per ceiling: a wall's length and height, a ceiling's length and width. "Add a room" adds the next one with its tables blank; "Add a section like this one" adds the next floor. Deducting openings is your call: CGC and CertainTeed count them as board, USG subtracts only the large ones.

Board: pick the type and thickness the spacing and the room ask for. NBC Table 9.29.5.3 and IRC Table R702.3.5 give the thickness by support spacing; Type X is the fire-rated core; moisture-resistant board is not for wet areas or directly behind tile in a shower, and tile around tubs and showers goes over a moisture-resistant backing (NBC 9.29.10.4, IRC R702.3.7). Type the sheet size from the product's data sheet and your waste: no maker publishes a waste figure. The sheets are exact on each row and rounded up once per product.

Fire separation: in Canada a house's own garage needs no fire separation, only an air barrier against fumes (NBC 9.10.9.18); suites are separated by 45 min, or by 12.7 mm board where a secondary suite allows it (9.10.9.16; Quebec limits that option to 3 units and 2 storeys). Table 9.10.3.1.-A rates stud walls (12.7 mm Type X one layer each side: 45 min). In the US, the garage side gets 1/2 in board and a ceiling under rooms 5/8 in Type X (IRC R302.6); an enclosed space under stairs 1/2 in (R302.7).

Finishing: in the Finishing section, type the board area once (the rooms' total, shown in the totals) and the rates from the data sheets: compound about 10 gal per 1,000 sq ft (USG; CGC prints 40.5 L/100 m²), paper tape about 370 ft per 1,000 sq ft, screws from the maker's tables (about 1,000 per 1,000 sq ft at 16 in framing). Beware of "per 100 m²" columns that repeat the per-1,000 sq ft numbers. The level of finish (GA-214, 0 to 5) sets how many coats go on. Fasteners follow NBC 9.29.5.8 and 9.29.5.9, IRC Table R702.3.5 and GA-216; ASTM C840 is the application standard.

Quebec: the Construction Code, Chapter I (the NBC 2020 modified for Quebec) applies since 2025-04-17; work begun before 2027-10-17 may still follow the previous edition. Its Quebec changes leave 9.29 as is and limit 9.10.9.16. In cold weather keep the space at 10 °C or more for 48 h before and after taping (NBC 9.29.5.10).

Older homes: Health Canada lists paint, putty, drywall, caulking, sealants and spackling among older materials that may contain asbestos, and lead paint is likely before 1960 (possible until 1990; the US EPA RRP rule covers homes built before 1978). Do not sand or break a suspect surface: only a laboratory test tells.

Sources

  • CertainTeed, installation guide Manufacturer dataInstall Like the Pros, Drywall Installation Guide, CertainTeed, 07-03-5180-US-EN, 04/25 (French 07-00-3919-CA-FR, 2/24). Checked Oct 8, 2026
  • USG, installation guide Manufacturer dataUSG Sheetrock Brand Installation and Finishing Guide, USG Corporation, J371/rev. 9-15. Checked Oct 8, 2026
  • GA-223 Trade associationGypsum Panel Products Types, Uses, and Standards (GA-223), Gypsum Association, GA-223-2024. Checked Oct 8, 2026
  • IRC 2021, R702.3.7 CodeInternational Residential Code 2021, R702.3.7 Water-resistant gypsum backing board, International Code Council, 2021. Checked Oct 8, 2026
  • National Gypsum, construction guide Manufacturer dataNGC Construction Guide, National Gypsum Company, 15th edition, 2022. Checked Oct 8, 2026
  • IRC 2021, R702.3.5 CodeInternational Residential Code 2021, R702.3.5 Application of gypsum board (Table R702.3.5), International Code Council, 2021. Checked Oct 8, 2026
  • GA-216 Trade associationApplication and Finishing of Gypsum Panel Products (GA-216), Gypsum Association, GA-216-2021 (the free edition; GA-216-2024 is sold). Checked Oct 8, 2026
  • USG, all purpose compound Manufacturer dataUSG Sheetrock Brand All Purpose Joint Compound, submittal sheet, USG Corporation, J1969-USA-ENG/rev. 6-22. Checked Oct 8, 2026
  • USG, paper joint tape Manufacturer dataUSG Sheetrock Brand Paper Joint Tape, submittal sheet, USG Corporation, J443727-USA-ENG/7-26. Checked Oct 8, 2026
  • ASTM C840 paywalled StandardASTM C840-25, Standard Specification for Application and Finishing of Gypsum Board, ASTM International, C840-25. Checked Oct 8, 2026
  • GA-214 Trade associationLevels of Finish for Gypsum Panel Products (GA-214), Gypsum Association, GA-214-2026 (French quick reference: 2022). Checked Oct 8, 2026
  • IRC 2021, R302.6 CodeInternational Residential Code 2021, R302.6 Dwelling and garage fire separation, International Code Council, 2021. Checked Oct 8, 2026
  • IRC 2021, R302.7 CodeInternational Residential Code 2021, R302.7 Under-stair protection, International Code Council, 2021. Checked Oct 8, 2026
  • EPA, RRP rule GovernmentRenovation, Repair and Painting Program: Contractors, US Environmental Protection Agency, updated 2026-03-31. Checked Oct 7, 2026
  • CGC handbook Manufacturer dataThe Gypsum Construction Handbook (CGC, Centennial Edition), CGC Inc. Centennial Edition, 2005. Checked Oct 8, 2026
  • NBC 2020, Table 9.10.3.1.-A CodeNational Building Code of Canada 2020, Table 9.10.3.1.-A Fire and sound resistance of walls, National Research Council of Canada, 2020 (Quebec: Code de construction, chapitre I, in force 2025-04-17). Checked Oct 8, 2026
  • NBC 2020, 9.29.10.4 CodeNational Building Code of Canada 2020, 9.29.10.4 Moisture-resistant backing, National Research Council of Canada, 2020 (Quebec: Code de construction, chapitre I, in force 2025-04-17). Checked Oct 8, 2026
  • CertainTeed, M2Tech Manufacturer dataM2Tech Drywall Panels, data sheet, CertainTeed Canada, 07-11-937-CA-EN, 10/24 (French 07-11-938-CA-FRCN). Checked Oct 8, 2026
  • NBC 2020, 9.29.5.3 CodeNational Building Code of Canada 2020, 9.29.5.3 Maximum spacing of supports, National Research Council of Canada, 2020 (Quebec: Code de construction, chapitre I, in force 2025-04-17). Checked Oct 8, 2026
  • CGC, all purpose compound Manufacturer dataCGC Sheetrock Brand All Purpose Drywall Compound, data sheet, CGC Inc. J2173-CAN-ENG/rev. 4-26 (French J2173-CAN-FRE). Checked Oct 8, 2026
  • CertainTeed, ready-mix compounds Manufacturer dataCertainTeed Ready-Mix Joint Compounds, data sheet, CertainTeed Canada, CTG-4043, 04/21. Checked Oct 8, 2026
  • NBC 2020, 9.29.5.9 CodeNational Building Code of Canada 2020, 9.29.5.9 Spacing of screws (and 9.29.5.8, nails), National Research Council of Canada, 2020 (Quebec: Code de construction, chapitre I, in force 2025-04-17). Checked Oct 8, 2026
  • NBC 2020, 9.29.2.1 CodeNational Building Code of Canada 2020, 9.29.2.1 Waterproof wall finish, where required, National Research Council of Canada, 2020 (Quebec: Code de construction, chapitre I, in force 2025-04-17). Checked Oct 8, 2026
  • NBC 2020, 9.10.9.18 CodeNational Building Code of Canada 2020, 9.10.9.18 Separation of storage garages, National Research Council of Canada, 2020 (Quebec: Code de construction, chapitre I, in force 2025-04-17). Checked Oct 8, 2026
  • NBC 2020, 9.10.9.16 CodeNational Building Code of Canada 2020, 9.10.9.16 Separation of residential suites, National Research Council of Canada, 2020 (Quebec: Code de construction, chapitre I, in force 2025-04-17). Checked Oct 8, 2026
  • Health Canada, asbestos GovernmentAsbestos and your health, Health Canada, modified 2023-02-10. Checked Oct 8, 2026
  • Health Canada, lead paint GovernmentLead-based paint, Health Canada, modified 2026-10-02. Checked Oct 7, 2026
  • NBC 2020, 9.29.5.10 CodeNational Building Code of Canada 2020, 9.29.5.10 Low temperature conditions, National Research Council of Canada, 2020 (Quebec: Code de construction, chapitre I, in force 2025-04-17). Checked Oct 8, 2026
  • RBQ, chapter I GovernmentRégie du bâtiment du Québec, Construction Code, Chapter I, Building (NBC 2020 modified for Quebec), Régie du bâtiment du Québec, page consulted 2026-10-08. Checked Oct 8, 2026